Eicon Networks S93 Guia de Instalação Página 99

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 98
Installation in Unattended Mode 99
For the proper setting, refer to the documentation that came with your PBX.
Call Reference Format:
Set the call reference format for your PBX type. Possible settings are:
0 (Standard): The call reference length is two bytes.
1 (Short): The call reference length is one byte.
For the proper setting, refer to the documentation that came with your PBX.
QSIGLogicalChannelId:
If you are using an E1 primary rate line, specify if your PBX assigns the channel IDs of
the B-channels according to time slots or continuous numbering to ensure correct
switching of the B-channels. Possible settings are:
0: Time slots
1: Continuous numbering.
For the proper setting, refer to the documentation that came with your PBX.
An E1 line has 32 time slots. Time slot 0 is used for synchronization. Time slots 1 to 15
are used by the first fifteen physical B-channels. Time slot 16 is used by the D-channel
and time slots 17 to 31 are used by the next fifteen B-channels.
If your PBX assigns the channel ID according to time slots, the channel ID is identical to
the time slot that the B-channel uses.
If your PBX numbers the B-channels continuously, the channel ID is not identical to the
used time slot. For example, channel ID 16 corresponds to time slot 17.
Since the applications assume that the channel IDs are identical to the used time slots,
the line must provide an interpretation of the IDs for continuous numbering. Thus, correct
switching of the B-channels is ensured.
Settings for North American protocols in combination with basic rate lines
DisableAutoSpid
0: The AutoSPID function is enabled. If your switch supports AutoSPID, the Diva Server
adapter can detect and load the SPIDs and subscriber numbers automatically. You do
not need to enter them manually when initializing the ISDN line.
1: The AutoSPID function is disabled. In some cases, you may want to specify your
SPIDs and subscriber numbers manually. To be able to do so, set DisableAutoSpid to
1.